The building consists of a large multi-use indoor courts area, with associated training facilities, fitness and gymnasium spaces and changing/amenities areas.
Designed to Importance Level 3, the courts area structure consists of steel portal frames spanning 38m with an 11m knee height. Our design made use of good ground conditions to reduce the member sizes within the superstructure while still achieving the required deflection limits for SLS2.